1. Features |
|
TRIAC output, zero current turn-off
INput and output 4000V optically isolated
LED indicator
Internal varistor (MOV) and RC snubber dua l surge absorb protec t
Performance than price high, high reliability
100% tested at rated current ,CE compliant. |
|
|
2. Application
|
|
HGC series three phase solid state relays, adapting ignition-proof engineering plastic cover, filled with EPOXY, screw thread connection, have the features of hard structure,vibration-proof capability high, input driving current small convenient to interface with terminals of computer and various digital tele-control circuit. This series are widely used in the fields of petrochemical equipment, foodstuff-producing machines, packaging machines, textile and plastic mechanisms, tool numerical control, gymnasium equip. Specialities be the same with canker, aquosity request prevent explode scurvines circumstance, and often switch of occasion. |
|
|
|
3. Selecting Code |
|
|
|
|
4. Iutput parameters (Ta:25℃)
|
|
Input type |
D:DC Control |
A:AC Control |
Control voltage range |
3-32 VDC |
90-280 Vrms (50-60Hz) |
Turn-on voltage(Max.) |
3.0 VDC |
90 Vrms |
Turn-off voltage(Min.) |
1.0 VDC |
10 Vrms |
Nominal input impedance |
1500 Ohms |
60k Ohms |
Typical input current |
10mA@5 VDC 22mA@ 24 VDC |
5mA@220 VAC 2.2mA@110 VAC |
Max.Reverse voltage |
-32 VDC |
_ |
|
|
|
5. Output parameters (Ta:25℃) : |
|
Output current type |
10 |
15 |
25 |
40 |
Operating voltage range |
2:28 280VAC 3:48 480VAC |
Max. Load current |
10A |
15A |
25A |
40A |
Max. Surge current-Non repetitive (10ms) |
120Apk |
160Apk |
250Apk |
300Apk |
Max. I t for fusing(10ms) |
72 A2s |
128 A2s |
312 5 A2s |
450 A2s |
Thermal resistance junction to case(Rjc) |
2.5℃ /W |
2.3 ℃/W |
1.1℃ /W |
0.9 ℃/W |
Min. Off-state dv/dt |
250V/usec |
500V/usec |
250V/usec |
250V/usec |
Max. Over-zero voltage |
±35VAC |
Min. Load current |
100mA |
Max. On-state voltage drop |
1.5VAC@rated current |
Max. Off-state leakage current |
5mA,1mA /no RC @rated voltage |
Transient over voltage |
2:800Vpk 3:1000Vpk |
Operating frequency range |
47 63Hz |
Dielectric strength 50Hz 1Min( ) |
4000VAC input-output 2500VAC input/output-base |
Insulation resistance |
1000M 500VDC Voltage Test |
Vibration resistance Destructive Functional |
117.6mm/s2(12G),10-55 Hz double Amplitude of 2 mm 117.6mm/s2(12G),10-55 Hz double Amplitude of 2 mm |
Destructive FunctionalShock resistance |
Min.980m/s2(100G)(5 times each for X,Y,Z axis) Min.980m/s2(100G)(4 times each for X,Y,Z axis) |
Max. Capacitance |
8pF input-output |
Max. Turn-on time |
Zero voltage turn-on |
(1/2 cycle of load power)+1msec(DC input) (3/2 cycle of load power)+1msec(AC input) |
Random turn-on |
1msec |
Max. Turn-off time |
(1/2 cycle of load power)+1msec(DC input) (3/2 cycle of load power)+1msec(AC input) |
Ambient operating temperature |
-30℃ to 80 ℃ |
Ambient storage temperature |
-30℃ to 120 ℃ |
Ambient humidity relative |
45% to 85% |
Weight typical |
≤85g |
|
|
|
6. Diminsions |
|
|
|
|
7. Connection / wiring |
|
|
|
|